Not all lighting retrofits are created equal.
With the great Idaho Power rebates out right now many businesses are doing lighting retrofits. The most common retrofit is from T12 to T8. One thing to remember is that not all retrofits are the same. There are a lot of businesses that just get multiple bids from different electrical contractors and go with the cheapest, assuming that a retrofit is a retrofit. The cheapest bid is not always the best.
Below are some things to consider when looking at a retrofit.
1. What type of ballasts is the contractor using? The difference between a cheap generic ballast and a high efficiency (NEMA qualified) ballast can be approximately 7% in energy difference. The reason for are doing the retrofit is to save energy. The type of ballast that you use does matter how much energy is saved.
2. What type of light bulbs is the person using? Are they using a cheap off brand import? Are they using 700 or 800 series lamps? Are they using low wattage T8 lamps, or extra long life T8 lamps? If an extra long life bulb is being used? Any of these higher quality light bulbs can add a few dollars per fixture to the lighting retrofit. However, in the long run the cost may well be worth it. These are things that the business should find out before deciding which bid to select. It is very important to make an “apples to apples” comparison.
3. Is the person doing the lighting retrofit a licensed electrical contractor? In this economy there are a lot of people trying to make money where ever they can. Make sure that the person doing the lighting retrofits is licensed by your state.
4. What is the contractor doing with the old T12 fluorescent bulbs? Are they recycling the light bulbs or just throwing them away? We highly recommend businesses request a written certificate of recycling. If a contractor is actually recycling, they should have this on file from their recycler. If they cannot provide a written certificate then they are likely not actually recycling.
Monday, September 14, 2009
Sunday, September 13, 2009
Monday, September 7, 2009
8' lighting conversion kits
We are now selling conversion kits for 8' light bulbs. Many times with 8 foot T12 light bulbs we were previously just converting the T12 lights to T8s. However, the energy savings was only about 20%. Also the customer was still stuck with 8 foot light bulbs.
We are now selling a conversion kit that converts 8 foot T12 fixtures to back to back 4 foot light fixtures. There is a wide variety of bulb and ballasts combinations that can be used in these conversion kits.
We are typically able to cut energy costs by 50% when changing out 8' T12 light bulbs to back to back 4' T8s. Below is a picture with a standard T12 8' foot fixture on the left and one of our conversion kits on the right. The fixture on the right is using 50% less energy than the one on the yet it is producing more light and higher quality light.

Call us at 208-378-1889 to discuss how these could be used in your facility.
Idaho Power rebates on these conversion kits are terrific and really help reduce customer cost!
We are now selling a conversion kit that converts 8 foot T12 fixtures to back to back 4 foot light fixtures. There is a wide variety of bulb and ballasts combinations that can be used in these conversion kits.
We are typically able to cut energy costs by 50% when changing out 8' T12 light bulbs to back to back 4' T8s. Below is a picture with a standard T12 8' foot fixture on the left and one of our conversion kits on the right. The fixture on the right is using 50% less energy than the one on the yet it is producing more light and higher quality light.
Call us at 208-378-1889 to discuss how these could be used in your facility.
Idaho Power rebates on these conversion kits are terrific and really help reduce customer cost!